Laboratory testing facility capabilities of the AMCA Partner Lab—KTC - Korea Testing Certification

AMCA 210 Small Chamber
(MPIR1240)
Large Chamber
(MPIR1260)
Large Chamber
(MPIR1560)
Figure 12 Max Outlet Area - Perpendicular Rotation 1.368 m2 (14.72 ft2) 4 m2 (43.04 ft2) NA

Figure 12 Max Outlet Area - Parallel Rotation
(Vane Axial Fans Only)

0.77 m2 (8.29 ft2)

2.25 m2 (24.21 ft2)

NA
Figure 12 Max Outlet Area - Parallel Rotation 0.493 m2 (5.31 ft2) 1.44 m2 (15.49 ft2) NA
Figure 15 Max Inlet Area - Any Rotation NA 7.2 m2 (77.47 ft2)
Max Airflow at 0 in. wg 24.3 m3/s (51,383 cfm) 71.81 m3/s (151,855 cfm)
Max Static Pressure 2936.5 Pa (11.8 in wg) 6852.9 Pa (27.6 in wg)
Max Brake Horsepower

22 kW @ 3540
149 kW @ 1750

Max Dynamometer Speed 3540 RPM (22kW)
1750 RPM (All Others)
AMCA 300
Max volume of Test Unit with Duct Work 38.08 m3 (1344.8 ft3)
Frequency 63 125 250 500 1000 2000 4000 8000 LwA
Approx Min Fan Lw
Reverb Room (dB)
77 59 50 44 36 32 38 46 54