The purpose of this standard is to establish uniform methods for laboratory testing of air-circulating fans to determine performance (forward or reverse flow) in terms of airflow rate for rating, certification, or guarantee purposes.
Submit your comments:
Air Movement and Control Association International, Inc.
Comments:
Tommy Berg Nielsen on 2023-08-16 11:26:00
Section/Figure/Table No.: 8.7
Type of Comment: Editorial
Comment (justification):
The explanation of the values states that Q is in m³/h
Proposed Change:
It must be m³/s
Tommy Berg Nielsen on 2023-08-16 11:22:00
Section/Figure/Table No.: 8.2
Type of Comment: Editorial
Comment (justification):
In the calculation of Ambient air density Eq. 8.5 iit says that 273.15 must be subtracted from the temperature. It should say that 273.15 must be added to the temperature, to get the temperature in Kelvin
Proposed Change:
It should say that 273.15 must be added to the temperature, to get the temperature in Kelvin